Home Assistant fail-safe (heartbeat watchdog)¶
Recommended: install the HACS custom integration
(Home Assistant 2026.7+). It polls Solar GET /api/health (heartbeat_last_pulse)
and runs the watchdog inside HA — no YAML package and no Solar heartbeat helper entity.
Solar advances heartbeat_last_pulse in-process each control cycle. Settings → Safety
only configures shutdown grid-charge-at-max (graceful process exit), not an HA
input_datetime pulse.
When Solar stops or hangs, Home Assistant can detect a stale API pulse and enable grid charge at maximum current — the same resilience action Solar applies on graceful shutdown or via the kill switch.
Prerequisites¶
- solar-ai-optimizer reachable from Home Assistant — see Home Assistant setup
- HACS integration paired (or Supervisor discovery on HAOS add-on)
- For latching fail-safe: inverter grid charge enable switch + max current number in integration options
- Battery / grid charge max amps configured in Solar (used when the watchdog latches)
Configure the HACS watchdog¶
Open Configure on the Solar AI Optimizer integration:
| Option | Purpose |
|---|---|
| Grid charge enable switch | Turned on when heartbeat is stale beyond debounce |
| Max grid charge current | Number entity set to Solar’s max grid charge amps |
| Stale seconds | Max age of heartbeat_last_pulse before unhealthy (default 120) |
| Debounce seconds | How long unhealthy must persist before latch (default 120) |
Set both fail-safe entities or neither. See Home Assistant integration.
Verify Solar is cycling: GET /api/health should show a recent heartbeat_last_pulse,
and the integration Healthy binary sensor should stay on.
How it works (HACS)¶
Solar control cycle → advances heartbeat_last_pulse (in-process)
HACS polls /api/health → Healthy binary sensor / fail-safe watchdog
Unhealthy + debounce → switch.turn_on + number.set_value (max amps)
Solar graceful stop → grid ON + max current (Settings → Safety shutdown fail-safe)
Kill switch → grid ON + max current + pause + restore sheds
Legacy YAML package (do not use with HACS)¶
Older installs may still have
solar-optimizer-failsafe.yaml.
That package watched input_datetime.solar_optimizer_heartbeat, which current Solar
builds no longer write. Disable the package when using the HACS integration to avoid
double grid-charge actions. New installs should not import it.
Limitations¶
- API heartbeat requires the Solar process to run and answer
/api/health. - Graceful shutdown fail-safe does not run on
kill -9or power loss — rely on the HACS watchdog for hard crashes. - The HACS watchdog writes inverter entities directly; it does not call the Solar API for those writes (Solar may be down).
Health API¶
GET /api/health includes:
heartbeat_configured— alwaystrueon current builds (liveness is in-process)heartbeat_last_pulse— last control-cycle pulse (site-local ISO timestamp)
Metrics counters: heartbeat_pulses_total, heartbeat_failures.